Harwood has two types of needle valves; toggle needle valves and conventional needle valves. Toggle needle valves, generally used as isolation valves, are available for pressures to 200,000 psi. The “conventional” needle valves are used as a pressure release or let down valve. There are two body types for conventional needle valves; one for pressures up to 150,000 psi, and another for pressures to 200,000 psi. Features for both types include sensitive feel, non-rotating needles for no backlash, replaceable seats, needles, and packings, low torque for easy closing, and throttling capacity.
Needle Valve Features:
Service for liquids and gases for pressures up to 150,000 psi or 200,000 psi
Manually-operated
Low torque; easily closed against pressure
Replaceable seat and packings
Throttling capacity; sensitive feel
Non-rotating needle; no backlash
Needle Valve Options:
Release Valves For 200,000 PSI
These valves are typically used as pressure release or let down valves. They feature low torque requirement, making it easy to close against pressure, replaceable tungsten carbide needle, replaceable seat and packings, and a sensitive feel for bleeding off small amounts of pressure and throttling.
PRESSURE RATING, PSI
PART NUMBER
INLET PORT
OUTLET PORT
VALVE BODY
INSIDE SEAT DIA., IN.
DIMENSIONS, IN.
A
B
200,000
D-3156
12H-1
12H-1
Angle
0.052
10.25
2.7
200,000
D-3157
12H-1
4L
Angle
0.052
10.25
3.75
200,000
D-3158
12H-1
1/4 NPT
Angle
0.052
10.25
2.95
200,000
D-3159
12H-2
12H-2
Angle
0.052
10.25
3.75
200,000
D-3160
12H-2
4L
Angle
0.052
10.25
2.7
200,000
D-3161
12H-2
1/4 NPT
Angle
0.052
10.25
2.95
200,000
D-3162
3M
3M
Angle
0.052
11.75
4.95
200,000
D-3163
3M
4L
Angle
0.052
11.75
2.7
200,000
D-3164
3M
1/4 NPT
Angle
0.052
11.75
2.95
150,000
D-3165
6M
6M
Angle
0.052
9.75
3.75
150,000
D-3166
6M
1/4 NPT
Angle
0.052
9.75
2.94
125,000
D-3165
5M
5M
Angle
0.052
9.75
3.75
125,000
D-3166
5M
1/4 NPT
Angle
0.052
9.75
2.94
Needle Valves For 150,000 PSI
These are conventional style needle valves, useful in a variety of applications, mainly as a shut off valve, pressure release, and to isolate portions of a high pressure system.
PRESSURE RATING, PSI
PART NUMBER
PORT SIZE
VALVE BODY
INSIDE SEAT DIAMETER
DIMENSIONS, IN.
A
B
100,000
C-4132
4L
Angle
0.062
7.62
2.5
100,000
C-4133
4L
Tee
0.062
7.62
2.5
150,000
C-4134
6M
Angle
0.062
7.62
3.25
125,000
C-4134
5M
Angle
0.062
7.62
3.25
150,000
C-4135
6M
Tee
0.062
7.62
4
125,000
C-4135
5M
Tee
0.062
7.62
4
60,000
C-4136
6L
Angle
0.062
7.62
2.5
60,000
C-4137
6L
Tee
0.062
7.62
2.5
100,000
C-4138
8L
Angle
0.062
8.18
3
100,000
C-4139
8L
Tee
0.062
8.18
3.5
60,000
C-4140
9L-3
Angle
0.062
8.06
3
60,000
C-4141
9L-3
Tee
0.062
8.06
3.5
20,000
C-4142
9L-5
Angle
0.125
8.62
3
20,000
C-4143
9L-5
Tee
0.125
8.62
3.5
Toggle Needle Valves
Harwood’s toggle needle valves are typically used in a system to isolate a pressure vessel or test rig from the rest of the high pressure system. The toggle mechanism and handle allow for easy closing and opening even at the full 200,000 psi.
PART NUMBER
PRESSURE RATING
INLET PORT
OUTLET PORT
INSIDE SEAT DIAMETER
D-2681
150,000 psi
2M
2M
0.052″
D-2682
150,000 psi
2M
4L
0.052″
D-2683
150,000 psi
2M
1/4 NPT
0.052″
D-2684
200,000 psi
3M
3M
0.052″
D-2685
200,000 psi
3M
4L
0.052″
D-2686
200,000 psi
3M
1/4 NPT
0.052″
D-2687
125,000 psi
5M
5M
0.052″
D-2688
125,000 psi
5M
4L
0.052″
D-2689
125,000 psi
5M
1/4 NPT
0.052″
D-2690
200,000 psi
12H-2
12H-2
0.052″
D-2691
200,000 psi
12H-2
4L
0.052″
D-2692
200,000 psi
12H-2
1/4 NPT
0.052″
D-2693
200,000 psi
12H-1
12H-1
0.052″
D-2694
200,000 psi
12H-1
4L
0.052″
D-2695
200,000 psi
12H-1
1/4 NPT
0.052″
E-2364
50,000 psi
15F
15F
0.312″
E-2365
50,000 psi
15F
3/4 NPT
0.312″
E-2366
100,000 psi
16F
16F
0.156″
E-2367
100,000 psi
16F
1/2 NPT
0.156″
E-2368
50,000 psi
24F
24F
0.312″
E-2369
50,000 psi
24F
1″ NPT
0.312″
Newport-Scientific, Inc an ISO 9001:2015 Company
8246 Sandy Court Suite E Jessup, Maryland 20794 USA