- NARROW RANGE SENSORS

NARROW RANGE HYGROSENSORS
HYGRODYNAMICS HYGROSENSOR
Narrow Range Humidity Sensors
are designed for rapid, accurate, and reliable humidity measurement in a wide variety of applications.
FEATURES
Quick Response for Real Time Monitoring and Control
High accuracy, + 1 % RH for Class A, + 2 % RH for Class B
- NBS (NIST) Traceability
- High Resolution; High Reproducibility
- Dependable, Trouble-Free Operation
- Class A TH3 sensors measure RH and temperature with a + 2 ° F accuracy
- All Class A sensors are furnished with individual calibration curves of percent RH vs. 0-100% output. Calibration Curves cover the temperature range of 20 ° F to 140 ° F
DEW POINT SENSORS
DP RANGE | ||
COLOR CODE | @ 80°F + 2°F | PART NUMBER |
WHITE | -40°F to +15°F | 1205DM |
WHITE | -40°F to +10°F | 1205-2 |
RELATIVE HUMIDITY SENSORS
HUMIDITY RANGES AT CORRESPONDING DRY-BULB TEMPERATURE | COLOR | |||||
CODE | ||||||
TYPE H3 | TYPE | |||||
TH-3 | ||||||
40 ° F | 80 ° F | 120 ° F | CLASS A | CLASS B | ||
1.7 TO 8.6% | 1.6 TO 6% | 1.5 TO 4.8% | 4812 | 1205 | 4828 | WHITE |
4.4 TO 14% | 3 TO 10% | 2.4 TO 8% | 4814 | 1207 | 4829 | BLACK |
7 TO 20% | 5 TO 15% | 3.5 TO 11% | 4815 | 1209 | 4830 | BROWN |
15 TO 27% | 11 TO 23% | 9 TO 19% | 4816 | 1211 | 4831 | RED |
22 TO 39% | 18 TO 33% | 14 TO 27% | 4817 | 1213 | 4832 | ORANGE |
33 TO 51% | 26 TO 42% | 21 TO 36% | 4818 | 1215 | 4833 | YELLOW |
49 TO 68% | 41 TO 61% | 34 TO 55% | 4819 | 1217 | 4834 | GREEN |
60 TO 81% | 51 TO 74% | 41 TO 67% | 4820 | 1219 | 4835 | BLUE |
75 TO 94% | 68 TO 88% | 62 TO 83% | 4821 | 1223 | 4836 | VIOLET |
87 TO 99% | 81 TO 99% | 76 TO 97% | 4822 | 1225 | 4837 | GRAY |
Add Suffix "W" for Weatherproofing: for atmospheres with water condensation
Add Suffix "D" for Cellulose Acetate Wrap: for dusty or dirty environments
Add Suffix "K" for Lexan: high temperature or hydrocarbon environments
SPECIFICATIONS AND ORDER INFORMATION
Catalog Number | Product Name | Product Description | Add To Cart |
---|---|---|---|
1205 | White Sensor Class B | 1.4 to 6% RH at 80F°, +/-2% RH |
![]() |
1205-2 | White Sensor Class A | 0.4 to 6% RH at 80°F, +/-1% RH |
![]() |
1205DM | White Sensor for Dew Point | -40°F to +15°F, +/- 3°F dew point. Used in dew point monitors and with 6380DP series transmitters |
![]() |
1207 | Black Sensor Class B | 3.0 to 10.0% RH at 80°F, +/-2% RH. |
![]() |
1209 | Brown Sensor Class B | 5.0 to 15.0% RH at 80°F, +/-2% RH. |
![]() |
1211 | Red Sensor Class B | 11.0 to 23.0% RH at 80°F, +/-2% RH. |
![]() |
1213 | Orange Sensor Class B | 18.0 to 33.0% RH at 80°F, +/-2% RH. |
![]() |
1215 | Yellow Sensor Class B | 26.0 to 42.0% RH at 80°F, +/-2% RH |
![]() |
1217 | Green Sensor Class B | 41.0 to 58.0% RH at 80°F, +/-2% RH. |
![]() |
1219 | Blue Sensor Class B | 51.0 to 74.0% RH at 80°F, +/-2% RH. |
![]() |
1223 | Violet Sensor Class B | 68.0 to 88.0% RH at 80°F, +/-2% RH |
![]() |
1225 | Gray Sensor Class B | 81.0 to 99.0% RH at 80°F, +/-2% RH. |
![]() |
4812 | White Sensor Class A | 1.4 to 6% RH at 80°F, +/-1% RH |
![]() |
4814 | Black Sensor Class A | 3.0 to 10.0% RH at 80°F, +/-1% RH. |
![]() |
4815 | Brown Sensor Class A | 5.0 to 15.0% RH at 80°F, +/-1% RH. |
![]() |
4816 | Red Sensor Class A | 11.0 to 23.0% RH at 80°F, +/-1% RH. |
![]() |
4817 | Orange Sensor Class A | 18.0 to 33.0% RH at 80°F, +/-1% RH. |
![]() |
4818 | Yellow Sensor Class A | 26.0 to 42.0% RH at 80°F, +/-1% RH |
![]() |
4819 | Green Sensor Class A | 41.0 to 58.0% RH at 80°F, +/-1% RH. |
![]() |
4820 | Blue Sensor Class A | 51.0 to 74.0% RH at 80°F, +/-1% RH |
![]() |
4821 | Violet Sensor Class A | 68.0 to 88.0% RH at 80°F, +/-1% RH |
![]() |
4822 | Gray Sensor Class A | 81.0 to 99.0% RH at 80°F, +/-1% RH. |
![]() |
4828 | White Sensor Class A TH3 | 1.4 to 6% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4829 | Black Sensor Class A TH3 | 3.0 to 10.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4830 | Brown Sensor Class A TH3 | 5.0 to 15.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4831 | Red Sensor Class A TH3 | 11.0 to 23.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4832 | Orange Sensor Class A TH3 | 18.0 to 33.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4833 | Yellow Sensor Class A TH3 | 26.0 to 42.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4834 | Green Sensor Class A TH3 | 41.0 to 58.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4835 | Blue Sensor Class A TH3 | 51.0 to 74.0% RH at 80°F, +/-1% RH. Temp +/- 2°F. |
![]() |
4836 | Violet Sensor Class A TH3 | 68.0 to 88.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |
4837 | Gray Sensor Class A TH3 | 81.0 to 99.0% RH at 80°F, +/-1% RH. Temp +/-2°F. |
![]() |