- ACCESSORIES

Hygrodynamics Machine
Hygrodynamics

ACCESSORIES

A variety of support products are available to make full use of your

HYGRODYNAMICS

equipment.  If you don't see what you need, please contact us for assistance.  We offer many more items for special situations.

 

SPECIFICATIONS AND ORDER INFORMATION

Catalog Number Product Name Product Description Add To Cart
0900104Four Pin InsertMounts in sensor manifold between sensor and cable. Provides high pressure air tight seal.  Add To Cart
0900105Two Pin Insert, SolidMounts in sensor manifold between sensor and cable. Provides high pressure air tight seal.  Add To Cart
0900106Two Pin InsertMounts in sensor manifold between sensor and cable. Provides high pressure air tight seal.  Add To Cart
1000602Gasket G1/2Gasket for 1450 Sensor  Add To Cart
1000613GasketSealing gasket for two pin insert or four pin insert. Used in sensor manifold.  Add To Cart
1835002OEM Dew Point Monitor Board Display BezelUse when mounting 6392 boards to a panel. Provides finished look around LED display cutout.  Add To Cart
1900212Sensor Duct Mount Flange for 1828Square plate for mounting 1828 sensor on ductwork.  Add To Cart
1900213Sensor Wall Mount Bracket for 1828Right angle plate for mounting 1828 sensor on wall.  Add To Cart
3300101Sensor Manifold, Square, Anodized AluminumHigh pressure manifold in a rectagular shape to house sensor. Has six #10-32 tapped holes for mounting and two 1/8" NPT female ports for air connections. Requires two pin or four pin insert, hex nut, and gasket to make complete assembly.  Add To Cart
3300104Sensor Manifold, Round, Black PlasticHigh pressure manifold in a cylindrical shape to house sensor. Has two #8-32 tapped holes for mounting and two 1/8" NPT female ports for air connections. Requires two pin or four pin insert, hex nut, and gasket to make complete assembly.  Add To Cart
3300105Sensor Manifold for 1450, Round, Black PlasticHigh pressure manifold in a cylindrical shape to house model 1450 type sensor. Has two #8-32 tapped holes for mounting and two 1/8" NPT female ports for air connections. Requires o-ring gasket to make complete assembly.  Add To Cart
3305005Inline FilterReplacement air filter used on vacuum pump assisted dew point monitors such as 8072. Captures plastic and dessicant particles to keep sensor area clean.  Add To Cart
4100132Plastic TubingClear Plastic tubing that is connected to the air flow which is 3/16"id x 5/16" od x 1/16 wall.  Add To Cart
4100133Thermoplastic TubingFlexible tubing for high temperature and low dew point sampling 3/16 id x 1/16 wall  Add To Cart
4600204Hex Nut, 1-1/4" DelrinSecures sensor insert into manifold.  Add To Cart
6016-1183m (118") Cable, 1450 SensorUsed to connect model 1450 sensor to 6392S series board  Add To Cart
6017-120.3m (12") Cable, 1420 SensorUsed to connect model 1420 sensor to 6392V series boards  Add To Cart
6019-12Cable 12" with Female End / Two LeadsThis cable comes standard with our popular 8098 series Dew Point Monitors. Other lengths are available.  Add To Cart
6019-66" Cable, Female End / Two LeadsThis is a 6" Cable used in our popular Model 8072 Dew Point Monitor.  Add To Cart
6020-120Round Cable 120" with Female End / Two LeadsThis cable is supplied with our popular 8097 series monitor, but different lengths are available.  Add To Cart
6020-726' Cable, Female End with Two LeadsUsed to connect Narrow Range sensor, manifold, or pipe mount directly to PC boards with terminal block such as 6380NR, 6392N, and 6390 series Humistats.  Add To Cart
60256' Cable, Male and Female EndsUsed to connect Narrow Range sensor, manifold, or pipe mount to a product with female sensor receptacle such as an enclosed Humistat.  Add To Cart
6025A6' Cable, Spade Lugs and Female EndUsed to connect Narrow Range sensor, manifold, or pipe mount to a product with screw terminals.  Add To Cart
602612' Cable, Male and Female EndsUsed to connect Narrow Range sensor, manifold, or pipe mount to a product with female sensor receptacle such as an enclosed Humistat.  Add To Cart
60282' Cable, Male and Female EndsUsed to connect Narrow Range sensor, manifold, or pipe mount to a product with female sensor receptacle such as an enclosed Humistat.  Add To Cart
602925' Cable, Male and Female EndsUsed to connect Narrow Range sensor, manifold, or pipe mount to a product with female sensor receptacle such as an enclosed Humistat.  Add To Cart
6064-1515" Cable with Four Pins and Four LeadsThis cable is used in our popular 8092 model.  Add To Cart
6064-726' Cable, Four Pins with Four LeadsUsed to connect Wide Range sensor, manifold, or pipe mount directly to PC boards with terminal block such as 6380WR, 6380DP, and 6392W.  Add To Cart
6146ASensor Pipe Mount, 300PSITwo pin sensor pipe mount for narrow range sensors. 1" NPT male pipe fitting is 300PSI rated.  Add To Cart
6149ASensor Pipe BushingConverts G1/2 thread to 1" Male NPT thread  Add To Cart
6245Dessicant TubeReplacement dessicant tube used to test vacuum assisted dewpoint monitors such as 8072. Provides a reliable source of dry air to verify the dewpoint monitor's basic operation.  Add To Cart
P1604030700O-ring GasketSealing gasket for sensor model 1420.  Add To Cart