- 6390/6340 SERIES HUMISTATS

6390/6340 SERIES HUMISTATS
HYGRODYNAMICS HUMISTAT HUMIDITY CONTROLLER/ALARM
HYGRODYNAMICS HUMISTAT Humidity Controllers are precision electronic circuits designed to regulate humidity conditions or to provide an alarm when moisture conditions deviate beyond acceptable limits.
FEATURES
-
Accuracy of + 1% or + 2% RH when used with our
field replaceable Hygrosensors
-
0 - 1 VDC or 0 - 100 µA output signals
-
Jumper selectable 115/230 VAC, 50 - 60 Hz
-
Low Power Consumption, 1 Watt
-
24V Models Available
A HUMISTAT can also monitor industrial process air. When used with an appropriate Hygrosensor, a HUMISTAT<.h2> can control desiccant dryer regeneration or monitor refrigerated dryer performance. With a variety of support accessories available, Newport Scientific, Inc. can specify a HUMISTAT system for most applications.
QUICK SELECTION GUIDE:
HUMISTAT PC BOARDS
6395- 115/230 VAC, DUAL RELAY, 0 - 1V OUTPUT
6396- 115/230 VAC, SINGLE RELAY, 0 - 100 µA OUTPUT
6397- 115/230 VAC, SPDT RELAY, 0 - 1V OUTPUT
6398- 115/230 VAC, SPDT RELAY, 0 - 1V OUTPUT (Based on shifted sensor curves)
ADD "-24V" to the part numbers above for 20V - 30V AC/DC Operation. Dimensions: 3.5" x 2.75" x 1.1"
ENCLOSED HUMISTATS
6345- 6395 IN ENCLOSURE
6346- 6396 IN ENCLOSURE
6347- 6397 IN ENCLOSURE
6348- 6398 IN ENCLOSURE
For Duct Mountable Configuration, add Suffix "D" to part numbers above.
SPECIFICATIONS AND ORDER INFORMATION
Catalog Number | Product Name | Product Description | Add To Cart |
---|---|---|---|
6345 | Dual Relay Humistat with Enclosure 0 - 1 Volt Output | Enclosed Humistat with two setpoint relays, 0-1V output, and bargraph display. Jumper selectable power 115/230VAC. |
![]() |
6346 | Single Relay Humistat with Enclosure 0 - 100uA Output | Enclosed Humistat with one setpoint relay, 0-100uA output. Jumper selectable power 115/230VAC. |
![]() |
6347 | Single Relay Humistat with Enclosure 0 - 1 Volt Output | Enclosed Humistat with one setpoint relay, 0-1V output. Jumper selectable power 115/230VAC. |
![]() |
6348 | Single Relay Humistat with Enclosure 0 - 1 Volt Output Calibrated to Old Sensor Curves | Enclosed Humistat with one setpoint relay, 0-1V output. Used in special applications with old sensor curves. Jumper selectable power 115/230VAC. |
![]() |
6394 | Single Relay Humistat PC Board 0 - 1mA Output | Humistat PC board with one setpoint relay, 0-1mA output. Jumper selectable power 115/230VAC. |
![]() |
6395 | Dual Relay Humistat PC Board 0 - 1 Volt Output | Humistat PC board with two setpoint relays, 0-1V output, and bargraph display. Jumper selectable power 115/230VAC. |
![]() |
6395-24V | Dual Relay Humistat PC Board 0 - 1 Volt Output | Humistat PC board with two setpoint relays, 0-1V output, and bargraph display. |
![]() |
6396 | Single Relay Humistat PC Board 0 - 100uA Output | Humistat PC board with one setpoint relay, 0-100uA output. Jumper selectable power 115/230VAC. |
![]() |
6397 | Single Relay Humistat PC Board 0 - 1 Volt Output | Humistat PC board with one setpoint relay, 0-1V output. Jumper selectable power 115/230VAC. |
![]() |
6397-24V | Single Relay Humistat PC Board 0 - 1 Volt Output | Humistat PC board with one setpoint relay, 0-1V output. |
![]() |
6398 | Single Relay Humistat PC Board 0 - 1 Volt Output Calibrated to Shifted Sensor Curves | Humistat PC board with one setpoint relay, 0-1V output. Used in special applications with shifted sensor curves. Jumper selectable power 115/230VAC. |
![]() |
6398-24V | Single Relay Humistat PC Board 0 - 1 Volt Output Calibrated to Shifted Sensor Curves | Humistat PC board with one setpoint relay, 0-1V output. Used in special applications with shifted sensor curves. |
![]() |